| Technical characteristics | Separator type |
| SXF-4-50 | SXF-4-150 | SXF-2-300 |
| 1. Size classes of sorted ores, mm | 10…60 | 30…150 | 60…300 |
| 2. Size classes ranges, mm | 10-40 20-40 20-50 20-60 | 30-80 30-100 40-120 40-150 | 60-200 80-250 100-250 150-300 |
3. Productivity, t/h * (according to the range) | 3-8 | 10-25 | 20-50 |
| 4. Initial X-ray emission source | Special portable X-ray apparatuses PXAS-50 |
| 5. X-ray emission detectors | Detecting blocks on the base of proportional gas meters |
6. Executive mechanisms type (occurrence frequency , Hz) | Quick-acting electromagnetic devices for ore moving direction changing |
ME 30(15-20) ME 80 (10-12) | ME 400 (6-8) | ME 2 (3-4) |
| 7. Sorting channels number. | 4 | 4 | 2 |
| 8. Electro-power voltage at alternative current frequency 50±1Hz, V | 220/380 | 220/380 | 220/380 |
| 9. Consumption power, kW, not more | 3,0 | 5,0 | 5,0 |
10. Gabarit sizes, mm 1) sorting machine (length х width х height)
2) operator's control unit (width х depth х height) |
3520х1200х3150
600х830х1300 |
5040х1500х3250
600х830х1300 |
5830х1500х3250
600х830х1300 |
11. Mass, kg, not more 1) sorting machine 2) operator's control unit | 1600 60 | 3900 60 | 4100 60 |
* Note.
Maximum productivity depends on:
Optimal productivity value is determined by technological XRS tests results taking into account sorted material size class.
Sorted ore (material) size class range is allowed to change according to technological tasks. Productivity norm is correcting accordingly.
OCS-А rating is carried out automatically due to rating device and turning mechanism of X-ray instrument.
| Physical method of ore quality determination | X-ray radiometric (X-ray fluorescent) |
| Analyzed elements range | From atomic number 20 and more |
| Analyzed material size | -500 mm (trucks, trolleys), -200 mm (conveyers) |
| Sensibility to main ore elements, % | 0,05..0,1 |
| Transport vehicle speed in the control zone, nor more | 6,0 kmph |
| Ore test time, not less | 2,0-3,0 s |
| Radiation zone width | 500..800 mm |
| The distance from X-ray block to the tested ore surface | 300..500 mm |
| Initial X-ray emission resource | X-ray emitter |
| Power voltage at alternative current frequency 50 Hz | 220 V |
| The module BX-RD gabarit sizes, mm, not more | Length - 1300 width - 1300 height - 800 |
| The Module BX-RD mass, kg, not more kg, | 200 |
Portable X-rays Complex
 |
Portable X-rays Complex
PXC-2 portable analyzers with the X-ray tube use
|